text.skipToContent text.skipToNavigation

RCBO 1-pole+N, 10 A, 0.30 A, C-Char, Type B SK, N right, short-time delayed

  1. DOEPKE FIC100,301+NBSK 3713070
Piece
RCBOs combine residual current and miniature circuit-breakers in a single device (RCBO). They protect people against residual currents and systems against short-circuit and overload. The FIB/FIC residual current operated circuit-breakers with integral overcurrent protection have a rated switching capacity of 6 kA. A tripping indicator and label window facilitate the overview. Type B switches are AC-DC sensitive. They protect against pulsating and AC residual currents, residual currents with mixed frequencies and smooth DC residual currents at frequencies up to 150 kHz. Switches with the characteristic curve SK ensure fault protection and a high system availability. They are characterised by a lower response sensitivity at higher frequencies. This means that system-related faulty tripping is largely prevented. The characteristic curve SK is optimised for systems in which no fire protection is required. Switches with tripping characteristic C are optimised for electric circuits with high inrush or peak currents. Standard switches are designed for electric circuits with a rated voltage of 230 V or 400 V and a rated frequency of 50 Hz. Properties: AC/DC sensitive for residual currents with frequencies of 0 Hz (smooth direct current) up to 150 kHz; mains-voltage-independent tripping when type A residual currents occur; compact design for all rated currents; high short-circuit resistance; switch position indicator; separate indication of fault cause; strain-relief clamps with a wide terminal cross-section range on both connection sides; Neutral conductor right; high electromagnetic compatibility (immunity to interference for industrial applications) 6 A - 10 A and 16 A - 32 A VDE certified; high immunity against transient leakage and residual currents thanks to slow tripping response; Mounting: quick fastening to mounting rail; any installation position; supply preferably from above; Application areas: commercial and industrial installations with TT, TN-S and TN-C-S systems, where power electronics equipment is used without galvanic isolation from the mains, e.g. frequency converters, switching power supplies, high-frequency converters. photovoltaic installations and UPS equipment with frequency converters without transformers; RCBOs with characteristic curve NK should be used where fire protection is legally required.; Hints: suitable for use in 50 Hz AC networks; RCBOs are also available for other frequencies upon request; not designed for use in direct current networks or on the output side of controlled electrical equipment such as frequency converters;